The layer order information you filled online doesn’t match the name suffix in gerber file

Reason of Failed Review:

We can’t recognize which layer(GP1 or GP2) should be GND layer and PWR layer.

Copper layer name suffix in your gerber is as below,

.GTL

.G1

.G2

.G3

.G4

.GP1

.GP2

.GBL

But layer order you filled online is L1:Top L2:Inner Layer1, L3:Inner layer 4, L4:Inner layer3 , L5: Inner layer 4, L6:Ground Plane, L7: Power Plane, L8: Bottom Side


Suggestion:

Please fill in the layer order information from top side view to bottom side according to the layer names in your gerber when you order multi-layer PCB.